3-7.
Remote 17
Receptacle
Information
()~
OUTPUT
(cONT~TOR)
D
Contactor on/off
signal;
+13 to +24 volts dc contactor on, 0 volts
dc
contactor
off.
REMOTE OUTPUT
CONTROL
A
+10 volts dc
output
to remote
control;
allows full control of MI
output
from
remote
control.
B
0 to +10 volts dc
input
command
signal
from
remote
control.
H
+24 volts
dc;
fused
at 1
ampere.
K
0 to +10 volts dc
output
to remote control set
by panel
AN
con
trol;
allows
percent
of
panel
AN control from
remote control.
L
24
volts
dc;
fused
at 1
ampere.
E/t~.
Cvicc
C
CVICC
select;
+13 to +24 volts dc selects
CV,
0 volts dc selects
CC.
G
Dig/inductance
control;
0 to +10 volts dc set
by panel Dig/
Inductance control.
A
~
AMPERAGE
~
~
VOLTAGE
E
Current
feedback;
+1 volt
dc per 100
amperes.
M
Voltage
feedback;
+1
volt dc per 10
arc
volts.
The
remaining
sockets
are
not
used.
REMOTE 17
Socket*
Socket Information
Ret. ST-Boo
764
GND
F
P
Circuit
common
for sockets
A, B, D, E, K,
and M.
S
Circuit
common
for sockets H and L.
3-8.
115 Volt AC
Receptacle
Chassis
common.
OM-167