KX-B520 Series
The LATCH signal is produced by the CPU, and fed to the Thermal Head directly.
Internal
Clock
PAPALLW
INT
Fig. 17 Equivalent Circuit
©
Binary Converting section
The gray level signal (DBO—DB4) from the shading correcting and A/D convert LSI (1C109) is
binary converted by the magnitude comparator.
Its signal is gated by PAPW signal.
As a result HDATA is an available signal in the CCD video signal.