Panasonic CS-A182KR Service Manual page 33

Hide thumbs Also See for CS-A182KR:
Table of Contents

Advertisement

: Unit centre should be at more than 540 mm
at right and left.
The height should be more than 195 mm
from the ceiling.
: From installation plate end to unit left side
end is 40 mm.
: From installation plate end to unit right side
end is 50 mm.
: Connecting cable should be about 750 mm
from this line. (Only for left rear piping)
1. Mount the installation plate on the wall with 6 screws. / (If
mounting the unit on the concrete wall, consider using anchor
bolts.)
- Always mount the installation plate horizontally by aligning
the marking-off line with the thread and using a level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
- Line according to the arrows marked on the lower left and
right side of the installation plate. The meeting point of the
extended line is the centre of the hole.
- Drill the piping hole at either the right or the left and the hole
should be slightly slant to the outdoor side.
10.2.3. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the wall.
Caution
When the wall is hollow, please be sure to use
the sleeve for tube ass'y to prevent dangers
caused by mice biting the connecting cable.
4. Finish by sealing the sleeve with putty or caulking compound at
the final stage.
33