DVA-1003B Technical Practice Addendum
While using the E & M control leads of the DVA-1003B and powering the DVA-1003B
from the supplied 12 volt DC adapter, you must connect the 12 volt adapter as shown
in the steps below, in order to get proper E & M lead operation from the DVA-1003B.
1. Disconnect the 12 volt adapter from the 120 volt wall power.
2. Cut off the power plug at the end of the 12 volt adapter's cord.
3. Strip back the two wires coming from the 12 volt adapter.
4. Connect the "striped" wire from the 12 volt adapter to the "-48V" screw terminal on
the DVA-1003B.
5. Connect the "solid" wire from the 12 volt adapter to the "GND" screw terminal on the
DVA-1003B.
-48V
GND
Striped Wire
Product Support Line...(715) 386-8666
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking
Electronics, its affiliates and/or subsidiaries assume no responsibility for errors and/or omissions contained in this information. Revisions of this
document or new editions of it may be issued to incorporate such changes.
6/15/99
Important:
Rear View of the DVA-1003B
USE ONLY
LISTED
CLASS 2
600 ohm
CO/PABX
POWER
E & M
SOURCE
E & M
12V xx xx
Protocols
0.5 A MAX.
1 2 3 4
CHANNEL 3
Solid Wire
Included 12 Volt Adapter
120V AC
Printed in the U.S.A.
600 ohm
CO/PABX
E & M
LINE
E & M
LINE
Protocols
1 2 3 4
CHANNEL 2
Fax Back Line...(715) 386-4345
600 ohm
CO/PABX
E & M
E & M
LINE
Protocols
1 2 3 4
CHANNEL 1
ZF301340 Rev A