Procedure
Check
Remarks
When the COPY START key
glows green, make two cop-:
ies of a single sheet docu-
ment. Before making the se-
cond copy, wait for at least
five seconds after the drum
has completely stopped.
There should be no-un-
usual: noise.
mo
The TONER OUT indicator
should flash five seconds
after the end of the sec-
ond copying operation.
Open the front door. Pull out
'|Ithe developing unit to the
stop.
ao
Shake the toner cartridge
vigorously.
Raise the cover of the develo-
ping unit hopper, invert the
toner cartridge and insert the
two tabs at the end of the
cartridge into the holes at
the rear of the developing
unit, Jay the toner cartridge:
flat, and pull it forward
slightly until it touches the
protrusion.
Hold the toner cartridge se-.
curely and slowly pull off the
seal toward the front.
Strike the top of the toner
cartridge to remove any
toner remaining in the toner
cartridge.
Remove the toner cartridge,
then place it in an empty box
and discard it.
Close the hopper cover, then
push in the developing unit.
to the rear.
Swing the developing unit
positioning lever clockwise.
Close the front door.
Set the power switch ON.
After the COPY START key
glows green, manually feed
six to ten sheets of blank
A3/Ledger size paper
through the copier.
Place a test sheet on the co-
pyboard, make a copy, then
check the copy image.
COPYRIGHT © 1988 CAKON IHC,
Copying operation should be
normal. If it is not normal,
make any required
adjustments.
CANON NP-1215 REV.0 MAR. 1968 PRINTED IN JAPAN (IMPRIME AU JAPON)