Aero testing guidance

CdA data is only as accurate as the inputs. Make sure you check Aerosensor's
settings in the ACS app before every test.
Always calibrate power sensor before starting testing. Small calibration offsets can
result in a big error in CdA measurement.
Always start and end your test block with a baseline repeat.
Try to maintain a constant speed through each run.
For out and back testing we recommend a stretch between 500 and 1000m.
The more out and backs you do, the better the repeatability will be.

Data Analysis

Data is recorded to FIT file. You can view the data in Garmin Connect, or download
the data to analyse in WKO or Golden Cheetah.
More analysis tools are coming soon. Keep an out for announcements on our
mailing list and social channels.
o We are shortly launching a collaboration with Aerotune to provide an online
platform tailored for Aerosensor analysis.
o There will also be Excel sheets that automate more in-depth analysis,
available on our website soon.