Adjustment
Adjustment conditions
point
LC-60/70EQ10U,SQ10U/15U/17U,TQ15U,UQ17U
[Adjustment standard value]
Measuring instrument: [TOPCON SR-UL2] Technical measuring instrument.
Level
Reference value
X=0.272
Point 7
928
y=0.277
X=0.2755
Point 6
784
y=0.2720
X=0.2755
Point 5
624
y=0.2720
X=0.2755
Point 4
432
y=0.2720
X=0.2755
Point 3
304
y=0.2720
X=0.2755
Point 2
192
y=0.2720
Remarks
Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
Brightness specification after adjustment.
LC-60SQ10U,15U,17U/EQ10U/TQ15U:Min 240cd/m2
LC-70SQ10U,15U,17U/EQ10U/TQ15U:Min 240cd/m2
5 – 14
Adjustment procedure
Adjustment spec
±0.0010
±0.0015
±0.0020
±0.0030
±0.0035
±0.0040
Inspection spec
±0.0020
±0.0030
±0.0040
±0.0060
±0.0070
±0.0080

Advertisement