¢ Temperature Setback Timer
• The temperature setback timer only changes the set temperature for 7 days, it cannot be used
to start or stop air conditioner operation.
• The temperature setback timer can be set to operate up to two times per day but only one
temperature setting can be used.
• During COOLING/DRY mode, the air conditioner will operate at a minimum of 18°C even if the
SET BACK temperature is set to 17°C or lower.
Case of Temperature Setback Timer on the Cooling operation. (Setting temperature :22°C,
SET BACK temperature :26°C)
SET BACK setting
Operation
temperature
*1
Operation
temperature
*1: During the SET BACK function,
the setting temperature is changed.
4-2. →ired remote control
ON
26°C
22°C
26°C
24°C
22°C
- (04-15) -
OFF
ON
Chenge the setting temperature:
22°C
24°C
OFF
4. Timer operation control