Basic Test Procedure; Tsw1400 Setup; Quick-Start Procedure; Send All, Save, Load, And Read All - Texas Instruments TSW1266EVM User Manual

Evaluation module
Table of Contents

Advertisement

www.ti.com
2.2.6
Send All, Save, Load, Read All
Section
Send All
Save
Load
Read All
2.2.7
USB Status
The indicator shows the status of the USB connection. The indicator is lit when the USB connection is
valid. If the computer is not connected to the board, click the Reset USB button.
2.2.8
Exit
Click to exit the GUI. Note that the X in the upper right corner of the window has been disabled to ensure
that the USB connection is closed properly.
3

Basic Test Procedure

3.1

TSW1400 Setup

See the TSW1400 User's Guide (SLWU079) for a more detailed explanation of the TSW1400 setup and
its features. This document assumes that the High Speed Data Converter Pro software and the TSW1400
pattern capture and generation board are both installed and functioning properly. This information can be
found at http://www.ti.com/tool/tsw1400evm.
3.2

Quick-Start Procedure

3.2.1
TSW1400 Data Capture Card
1. Connect a 5-V power supply to connector J12 of the TSW1400. Flip switch SW7 to the ON position.
2. Insert a USB cable into the USB port on the TSW1400. Connect the other end to the PC.
SLAU484 – January 2013
Submit Documentation Feedback
Figure 7. Send All, Save, Load, and Read All
Table 6. Send All, Save, Load, and Read All Descriptions
Description
Click to send all the registers for all devices. Press a few times if the board does not
seem to be responding correctly.
Save the register settings in a text file. Can be reloaded later to set the GUI and
devices to a known state.
Load a saved configuration.
This function is not currently enabled on the TSW1265 GUI.
Copyright © 2013, Texas Instruments Incorporated
Basic Test Procedure
TSW1266EVM Evaluation Module
9