General Precautions Use this appliance for its intended purpose only and follow these general precautions along with those listed throughout this guide: WARNING SHOCK HAZARD — Electrical Grounding Required. • Keep the unit unplugged throughout installation except during testing. • Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
Door Swing/Clearances Information Units have a zero clearance for the door to open 90° (see Figure 3). U-Line recommends a minimum door clearance of 3/4" to accommodate the flange if the unit is right-hand hinged and installed next to a wall or similar type of structure.
Reversing the Door All units may be left- or right-hand opening. Note: The grille should not yet be installed. If it has been installed, remove it for door reversing. See Page 10. To reverse the door: 1. Remove travel pin from cabinet (two screws).
Figure 12 Figure 11 9. Gently slide upper hinge through flange and fasten upper hinge to unit (three screws). Partially tighten screws. See Figure 11. 10. Place door on lower hinge pin. 11. Align door pivot hole with pivot hole in upper hinge and insert pivot screw into upper hinge and tighten securely.
4 Prepare and Install Door Panel (BI95BTP units only) Units will accept a Custom 1/4" Thick Insert to harmonize with or accent the surrounding decor. If this treatment is not included in this installation, go on to 5 Adjust Door. Custom 1/4"...
(see Figure 20). However, make certain that the tubing is not pinched or damaged during installation. • U-Line recommends the use of copper tubing for installation. To connect to water supply: 1. Install the 1/4 inch OD copper water line from the main water source.
Figure 18 Figure 19 2. Locate the compression fitting and ferrule packed with the unit. Slide the compression fitting and ferrule over the 1/4-inch OD water supply line. Do not use thread sealing compound or tape. Using two wrenches, tighten the compression fitting on the supply line (see Figure 18).
8 Level the Unit Leveling Information IMPORTANT It is extremely important that the unit sits on a level surface, as it does not have feet levelers. If it is not level, the ice mold will not fill evenly. Use a level to check the levelness of the unit from front to back and from side to side.
Hook-Hinge Figure 24 4. Insert the screw. Do not overtighten. Installation Troubleshooting Problem Water is leaking under the unit. Solution A water leak under the unit is most likely caused by a bad connection in the water supply line. Make sure the water line’s brass fitting is screwed tight to its valve and threaded correctly.
See the User Manual’s Troubleshooting Guide for more solutions. For more than four decades, U-Line has distinguished itself as the leader in built-in undercounter ice making, refrigeration and wine storage appliances. U-Line Corporation, located in Milwaukee, WI, is a family operated manufacturer of built-in undercounter icemakers, Combo refrigerators, refrigerated drawers and refrigerator/freezers.