3 Prepare Site
Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit
does not require additional air space for top, sides or rear.
However, the front grille must NOT be obstructed and
clearance is required for water and electrical connections
in the rear.
Note: Unit can NOT be installed behind a closed cabinet
door.

Cut-Out Dimensions

Filler Panel (Not Provided by U-Line) –
May Be Added Above or Below Unit
to Enclose for a Built-In Look
Typical
Counter
Height
34-1/4"
to
35-1/8"
Cut-Out
Height
28-5/8"
to
28-7/8"
8"
Figure 1
Follow the cut-out drawing in Figure 1. The 21-1/16"
width allows 1/4" for ease in installation and removal of
the unit. 24" is the counter depth in most installations.
The unit is 24" deep including the door and handle (see
Figure 2).
IMPORTANT
It is extremely important that the unit sits on a level
surface, as it does not have feet levelers. If it is not level,
the ice mold will not fill evenly.
www.U-LineService.com
CO29A and CO29FF Ice Maker/Refrigerators
See Electrical
Specifications
for Power Supply
24"
Minimum
21-1/16"

Product Dimensions

24"
Including
Handle
Figure 2

Door Swing/Clearances Information

Units have a zero clearance for the door to open
90° (see Figure 3). U-Line recommends a minimum door
clearance of 1/4" to accommodate the handle if the unit is
right-hand hinged and installed next to a wall or similar
type of structure.
Units require a minimum of 1" door clearance if installed
flush with cabinet or wall and 9" clearance if installed
adjacent to cabinet or wall if the unit is left-hand hinged
for easy removal of ice bin. See Figure 3.
4
28-1/2"
20-13/16"
02/2005