5.
Reinstall the oil fill cap/dipstick and tighten
securely.
NOTE: To prevent extensive engine wear or
damage, always maintain the proper oil
level in the crankcase. Never operate the
engine with the oil level below the "ADD"
mark or over the "FULL" mark on the
dipstick.
zyxwvutsr
I
Figure 8. Oil Drain Plugs and Oil Filter.
Service Oil Cooler
Some engines are equipped with an oil cooler. One
style of oil cooler mounts on the engine crankcase and
has the oil filter on it (see Figure 9). The other style of
oil cooler is mounted on the blower housing (see
Figure
zyxwvutsrqpo
lo), separate from the oil filter.
I
Figure 9. Crankcase Mounted Oil Cooler.
To service the crankcase mounted oil cooler, clean off
the outside fins with a brush or with compressed air.
I
Figure 10. Blower Housing Mounted Oil Cooler.
To service the blower housing mounted style oil cooler,
clean the outside of fins with a brush. See Figure 10.
Remove the two screws holding the cooler unit to the
blower housing. Tilt the cooler downward as shown in
Figure 11. Clean the inside of the cooler with a brush,
as shown in Figure 11, or with compressed air. After
cleaning, reinstall the oil cooler to the blower housing
with the two mounting screws.
Inspect and clean oil cooler every
25 hours of
operation (more frequently under severe conditions).
Oil cooler must be kept free of debris.
I
Figure 11. Cleaning Blower Housing Mounted Oil
Cooler.