Download Print this page

Clean And Care; Maintenance - Delta MultiChoice 17 Series Manual

Tub and shower faucet trim, valve trim
Hide thumbs Also See for MultiChoice 17 Series:

Advertisement

Available languages

Available languages

Clean and Care

Care should be given to the cleaning
of this product. Although its finish is
extremely durable, it can be damaged by
harsh abrasives or polish. To clean, simply
wipe gently with a damp cloth and blot dry
with a soft towel.

Maintenance

Faucet leaks from tub spout/hand shower:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge
RP46463 or RP32104
See Helpful Hints 1, 2 & 3.
Helpful Hints:
1. Before removing valve cartridge assembly for any
maintenance, be sure to note the position of the
rotational limit stop on the cap. The valve cartridge
assembly must always be put back in the same
position. BE SAFE! After you have finished the
installation, turn on valve to make sure COLD
WATER FLOWS FIRST.
2. To remove valve cartridge from body, shut off
water supplies and remove handle and bonnet nut.
Do not pry the valve cartridge out of the body with
a screwdriver. Place handle on stem and rotate
counterclockwise approximately 1/4 turn after the
stop has been contacted. Lift valve cartridge out
of body.
Units shipped in March
2006 and after.
17
Grey Upper Cap
V Notch
Adapter
Order RP46463 to
Replace Cartridge.
107529 Rev. F
Cartridge Summary Reference Sheet
Shorter Tab
Warning: Scrubbing Bubbles
®
Cleaner and Lysol
Cleaner must not be used on the clear knob
handles and levers. Use of these cleaners
can result in cracked or severely damaged
handles. If overspray gets onto the handles,
immediately wipe them dry with a soft
cotton cloth.
Remove seats and springs and replace.
Place the largest diameter of the spring into the
seat pocket first and then press the tapered end
of the seal over the spring. Reassemble valve
cartridge and replace in body following instructions
given in 1 above.
3. If the water in your area has lime, rust, sand
or other contaminants in it, your pressure
balance valve will require periodic inspection.
The frequency of the inspection will depend
on the amount of contaminants in the water. To
inspect valve cartridge remove it and follow the
steps in note 1 above. Turn the valve to the full
mix position and shake the cartridge vigorously.
If there is a rattling sound, the unit is functional
and can be reinstalled following instructions given
in note 1 above. If there is no rattle, replace the
housing assembly with the proper RP.
Units shipped before
1700
White Upper Cap
Square Notch
Order RP32104 to
Replace Cartridge.
12
®
Bathroom
Basin Tub and Tile
March 2006.
Longer Tab

Advertisement

loading