Sony KD-55X95 G Series Service Manual page 17

Table of Contents

Advertisement

2019/01/15 23:07:08 (GMT+09:00)
Retry Limitation by Remote/Power Key
Smart Core
Red LED
blinking
count
2x
MAIN_POWER
DC_ALERT (5V)
3x
AUD_ERR
LD_ERR
4x
BCM_ERR
5x
P_ID_ERR
6x
BACKLIGHT
7x
TEMP_ERR
8x
4KBE_ERR
*1) If STDWN_OFFON_CNT <= STDWN_RTRY_LIMIT, and STDWN_OFFON_CNT_MAIN_POWER <=
STDWN_RTRY_LIMIT_MAINPOWR, you can turn the set on by a remote/power key. At this time, if the error occurs again, the
STDWN_OFFON_CNT is incremented by 1.
*2) When the main micro operates normally for STDWN_OFFON_CLR = 60 minutes, STDWN_OFFON_CNT and
STDWN_OFFON_CNT_MAIN_POWER are cleared.
Error Name
Retry Permission Times
STDWN_RTRY_LIMIT_MAINPO
WR = 1
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
*1
Note
Number of off/on action for MAIN_POWER
shutdown is recorded to
STDWN_OFFON_CNT_MAIN_POWER
Number of off/on action during the error shutdown
is recorded to STDWN_OFFON_CNT.
.