Maintenance, Care & Cleaning; Cleaning The Condenser Coil - True TMC-49-S Installation Manual

True tmc-49-s: operation instruction
Hide thumbs Also See for TMC-49-S:
Table of Contents

Advertisement

True Food Service Equipment, Inc.
True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING

CLEANING THE CONDENSER COIL

When using electrical appliances, basic safety precautions should be followed, including the following:
REQUIRED TOOLS:
• Phillips Screwdriver
• Stiff Bristle Brush
• Adjustable Wrench
• Vacuum Cleaner
Step 1
Disconnect power to unit.
Step 2
Image 3.
Take off rear lower grill assembly by removing (2)
side screws.
Step 3
Remove bolts connecting frame rail cross bar to
allow access to compressor.
Step 4
Remove bolts anchoring compressor assembly to
frame rails and carefully slide out. (tube
connections are flexible)
Step 5
Clean off accumulated dirt from condensing coil
Image 4.
with a stiff bristle brush.
Step 6
Lift W.R. Board cover above fan at plastic plugs and
carefully clean condenser coil and fan blades.
Step 7
After brushing condenser coil vacuum dirt from
coil, and interior floor.
Step 8
Replace cardboard cover. Carefully slide
compressor assembly back into position and
replace bolts.
Step 9
Reinstall rear grill assembly onto unit with
appropriate screws. Tighten all screws.
Step 10
Connect unit to power and check to see if
compressor is running.
............ www.truemfg.com ............
9
9
............ www.truemfg.com ............
9
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tmc-58-sTmc-34-s