4. Check all connections for secure
fitting and tightness.
New injectors have their
position marked on their
packing or injector table on
Injector table, page 7 can be
referred to.
Flame failure device
Sparking plug
Injector
Burner
Unless there is an abnormal
condition, do not attempt to
remove the gas burner taps. You
must call an Authorised service
agent if it is necessary to change
the taps.
Reduced gas flow rate setting for
hob taps
1. Ignite the burner that is to be
adjusted and turn the knob to the
reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized
screwdriver to adjust the flow rate
adjustment screw.
For LPG (Butane - Propane) turn the
screw clockwise.
For the natural gas, you should turn
the screw counter-clockwise once.
» The normal length of a straight flame
in the reduced position should be 6-7
mm.
4. |f the flame is higher than the
desired position, turn the screw
clockwise. If it is smaller turn
anticlockwise.
5. For the last control, bring the
burner both to high-flame and
reduced positions and check
whether the flame is on or off.
Depending on the type of gas tap used
in your appliance the adjustment
screw position may vary
1
Flow rate adjustment screw
17 | EN