Mitsubishi Electric 700 Series Training Manual page 87

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

2. Monitor Screens
Operation method (Canceling the verify stop)
(1) Carry out the operations in "Operation
method (Registering verify stop)".
If the verify stop position is not displayed,
press the menu
(2) Press the menu
(Note) Verify stop can also be canceled during operation.
Precautions
(1) When registering the stop position (O, N, B values), confirm that the block exists in the searched program.
Verify stop will not be executed if the corresponding block is not found at the registered stop position.
(2) Always set one of the O, N or B numbers. If nothing is set, a setting error will occur.
(3) If the O No. is not set, the O No. used during operation search will be used.
(4) If the N and B numbers are not set, the block will be searched using the O No.
(5) If there are several sequences and blocks with the same number in one program, verify stop will be
executed after executing the first block that matches in the execution order.
(6) The settings are canceled when verify stop is executed.
(7) The settings are canceled when reset is executed.
(8) If only the program number is set, verify stop will take place at the head of the program only when there is
a program number at the first line.
(9) Verify stop / Verify stop cancel cannot be performed for blocks being executed or blocks already read into
the preread buffer.
(10) Verify stop is not performed in the tapping mode.
(11) Verify stop is possible in a subprogram, but is not possible in a machine tool builder macro program.
(12) If verify stop is set for a fixed cycle block, verify stop will be executed after the positioning block is
completed.
(13) Verify stop is possible even when editing is locked.
(14) Verify stop is executed after executing the block set for the verify stop position. If the verify stop position
is set in a program call (M98) block, verify stop will be executed before the subprogram is called.
(15) If the set block is set to be skipped, verify stop will not be executed.
(16) The verify stop position can be registered for each part system.
(17) The stop position cannot be registered during verification.
(18) Registration of verify stop position is not possible for a program with 33 or more file name characters.
(19) In the case where the device is HD, memory card, DS, or FLD at the time of verify stop position
registration, inputting "0//" will be resulted in a setting error.
Stop position .
Stop cancel .
The verify stop position appears.
The stop position displayed on the screen is cleared, and the
[Verifying] display is erased.
79
2.21 Verify Stop

Advertisement

Table of Contents
loading

This manual is also suitable for:

70 series

Table of Contents