Amana PBH113B35MA Installation Instructions And Owner's Manual
Amana PBH113B35MA Installation Instructions And Owner's Manual

Amana PBH113B35MA Installation Instructions And Owner's Manual

Thru-the-wall room air conditioner with optional electric heat

Advertisement

Quick Links

Thru-the-Wall
Room Air Conditioner
with optional Electric Heat
Contents
IMPORTANT NOTE TO THE OWNER ........................... 2
IMPORTANT NOTE TO THE SERVICER ....................... 2
Unit Features ................................................................ 2
Transportation Damage .............................................. 2
Unpacking The Unit ..................................................... 2
Parts Supplied ............................................................. 2
Unit Accessories ........................................................... 3
Operating Instructions ................................................. 3
Installation Instructions ............................................... 3
Wiring ........................................................................... 6
Unit Operation ............................................................. 6
Preventative Maintenance .......................................... 8
Obtaining Service ........................................................ 9
Warranty ..................................................................... 10
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to
know the product better than the customer. This
includes all safety precautions and related items.
Prior to actual installation, thoroughly familiarize
yourself with this Instruction Manual. Pay special
attention to all safety warnings. Often during
installation or repair it is possible to place yourself
in a position which is more hazardous than when
the unit is in operation.
IO-291
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
Installation Instructions
and Owner's Manual
This manual must be left with the owner
of the equipment.
WARNING
HIGH VOLTAGE!
Disconnect ALL power before servicing
or installing. Multiple power sources may
be present. Failure to do so may cause
property damage, personal injury, or death.
Remember, it is your responsibility to install the
product safely and to know it well enough to be able
to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of
thinking before acting. Most dealers have a list of
specific good safety practices...follow them.
The precautions listed in this Installation Manual
are intended as supplemental to existing practices.
However, if there is a direct conflict between existing
practices and the content of this manual, the
precautions listed here take precedence.
March 2006

Advertisement

Table of Contents
loading

Summary of Contents for Amana PBH113B35MA

  • Page 1: Table Of Contents

    Thru-the-Wall Installation Instructions Room Air Conditioner and Owner’s Manual with optional Electric Heat This manual must be left with the owner of the equipment. Contents WARNING IMPORTANT NOTE TO THE OWNER ......2 HIGH VOLTAGE! IMPORTANT NOTE TO THE SERVICER ....... 2 Disconnect ALL power before servicing Unit Features ..............
  • Page 2: Important Note To The Owner

    ® If the sleeve is an Amana brand wall sleeve, use the TWKGSLV rear louver panel kit. If the sleeve is an Emerson wall sleeve, use the TWEAK2 adapter kit, If the sleeve is...
  • Page 3: Installation Instructions

    A TWKGSLV rear louver panel kit is required for unit in the bottom right side of the sleeve with #8 x 3/8” blunt ® installation into an existing Amana brand 26” wall sleeve. A point sheet metal screw. The hole on the sleeve is TWEAK2 or TWFAK2 adapter kit is required for unit instal- indicated by grounding symbol on the sleeve.
  • Page 4 Locking Plate Figure 3 3. Remove shipping pads inside air conditioner next to Figure C compressor. (See Figure B.) 6. If outlet is on the left side of the unit. route power cord as shown in Figure D. Power Remove shipping Cord pads...
  • Page 5 To replace front grille: Grille EXHAUST AIR VENT Figure 4 AIR DIRECTION: Horizontal louvers on the front grille let you control the air Hook the tabs on the front grille even with the tabs on the direction up and down. case and snap into place.
  • Page 6: Wiring

    Remove the front grille to adjust the vertical louvers side-to- Wiring side to direct the air left or right. Before wiring the unit, please review the following warnings and cautions. WARNING To avoid the risk of electrical shock, personal injury or death, do not service this unit without first opening all disconnects and/or removing the unit cord set plug from the wall outlet.
  • Page 7: Unit Operation

    NOTE: If the fan cycle switch (see Additional Control Inputs) VOLTAGE MEASUREMENTS is in the CYCLE mode, both the compressor and fan will Before connecting the unit, measure the supply voltage. cycle on and off during the cooling modes. Voltage must fall within the voltage utilization range given in Table 1.
  • Page 8: Preventative Maintenance

    Wait 3 minutes to restart ADDITIONAL CONTROL INPUTS 70° HIGH HIGH NOTE: Not available on all models. COOL HEAT Fan Cycle Switch The fan cycle switch is located behind the plastic front assembly underneath the control knob (Figure 9). The fan HEAT COOL 55°...
  • Page 9: Normal Operating Sounds And Conditions

    Normal Operating Sounds and Conditions COMPRESSOR The compressor is hermetically sealed, permanently lubri- cated and requires no additional oiling. POPPING OR GURGLING SOUNDS This sound is the refrigerant traveling through the lines. This is a normal sound which may be heard for a few seconds after FRONT PANEL AND GRILLE the unit shuts off.