USER GUIDE
TEMPERATURE CONTROL SPECIFICATIONS
Double Throw Ice Maker Thermostat Numbers 4548,
AR-19-12, 2636, 2690, 2691, 2717, 2783, 2782-S, 2763-S,
2780, 80-26005-02
These temperature controls are double throw, single pole
controls. The sensing tube is inserted into the ice maker mold
and senses mold temperature. After ice is sensed in the
mold, the 2-3 contacts open (stopping the compressor) and
the 2-1 contacts are closed (starting the ice maker motor).
The 2-3 contacts close (2-1 contacts open) before the end of
the ice harvest cycle.The hold switch prevents power going
back to the compressor. This prepares the control for the next
cycle.
YELLOW WIRE
CONNECTION
2
FREEZE POSITION
Troubleshooting Extended
2
ICE MAKER CONTROL
CYCLE
FREEZE
HARVEST
Figure 5. Temperature Controls - Manual Defrost Ice Makers
1
3
1
2
3
ICE HARVEST POSITION
OPEN
CIRCUIT
2 - 1
2 - 3
43
.
RED WIRE
CONNECTION
BLUE/BLACK WIRE
CONNECTION
183-8
1
3
CLOSED
CIRCUIT
2 - 3
2 - 1
183-9