Item
Maximum temperature limit
Current temperature
Desired temperature
Submenu
5.3.4

Detailed screen with values

a
c
b
a
Settings
b
Values
c
Selected setting and value
Possible actions on this screen
Go through the list of settings.
Change the value.
Go to the next setting.
Confirm changes and proceed.
5.4

Turning operation ON or OFF

5.4.1

Visual indication

Certain functionalities of the unit can be enabled or disabled
separately. If a functionality is disabled, the corresponding
temperature icon in the home screen will be greyed out.
Space heating/cooling operation
a
55
45
21
35
a
Space heating/cooling operation ON
b
Space heating/cooling operation OFF
Tank heating operation
c
55
45
21
35
c
Tank heating operation ON
EBSH/X(B)11+16P30+50D
Daikin Altherma 3 R ECH₂O
4P663485-1C – 2023.05
Description
b1 Fixed by the unit
b2 Restricted by the installer
c
Measured by the unit
d
Turn the right dial to
increase/decrease.
e
Turn or press the left dial to
go to the submenu.
Example:
7.2.1
Time/date
Hours
11
30
Minutes
a
c
b
b
55
45
21
35
d
55
45
21
35
d
Tank heating operation OFF
5.4.2

To turn ON or OFF

Space heating/cooling operation
NOTICE
Room frost protection. Even if you turn OFF space
heating/cooling operation ([C.2]: Operation > Space
heating/cooling), room frost protection operation –if
enabled– can still activate. However, for leaving water
temperature control and external room thermostat control,
the protection is NOT guaranteed.
1 Go to [C.2]: Operation > Space heating/cooling.
C.2
Operation
Space heating/cooling
On
Tank
Off
2 Set operation to On or Off.
Tank heating operation
NOTICE
To ensure safe operation of the system, do NOT turn off
DHW when space heating is required.
NOTICE
Disinfection mode. Even if you turn OFF tank heating
operation ([C.3]: Operation > Tank), disinfection mode will
remain active. However, if you turn it OFF while
disinfection is running, an AH error occurs.
1 Go to [C.3]: Operation > Tank.
C.3
Operation
Space heating/cooling
On
Tank
Off
2 Set operation to On or Off.
5.5

Reading out information

To read out information

1 Go to [8]: Information.

Possible read-out information

In menu...
[8.1] Energy data
[8.2] Malfunction history
[8.3] Dealer information
[8.4] Sensors
[8.5] Actuators
[8.6] Operation modes
5 Operation
You can read out...
Produced energy, consumed
electricity, and consumed gas,
energy flow diagram
Malfunction history
Contact/helpdesk number
Room, tank or domestic hot
water, outside, and leaving water
temperature (if applicable)
Status/mode of each actuator
Example: Domestic hot water
pump ON/OFF
Current operation mode
Example: Defrost/oil return
mode
Operation manual