Navien NHW700 Installation Manual page 42

Non-condensing water heaters
Hide thumbs Also See for NHW700:
Table of Contents

Advertisement

3.5.3 Measuring Vent Length (Indoor Models Only)
Refer to the table to find the maximum vent length based on the number of elbows. (Two 45 degree elbows
count as one 90 degree elbow.)
Vent Type
Concentric
The Maximum Vertical and Horizontal (Total) Vent Length does not include any elbows.
Note
Each 90° elbow is equivalent to 5 feet of vent length.
Two 45° elbows are equivalent to one 90° elbow.
The value in the table include the terminating vent length.
NaviVent Vent Components
Diameter
3 in. / 5 in.
(80 mm / 125 mm)
Number of 90° Elbows
0
1
2
3
Equivalent Length
3 ft (91 cm)
5 ft (1.5 m)
5 ft (1.5 m)
Maximum Vent Length
20 ft (6 m)
15 ft (4.5 m)
10 ft (3.0 m)
5 ft (1.5 m)
Installing the Water Heater