Navien NHW700 Installation Manual page 29

Non-condensing water heaters
Hide thumbs Also See for NHW700:
Table of Contents

Advertisement

3.4.2 Using the Water Heater for
Combination Water Heating and Space
Heating
When using the water heater for both water
(potable) heating and space heating, follow these
guidelines:
Ensure that all piping and components connected
the water heater are suitable for potable water
applications.
Do not introduce toxic chemicals, such as water
treatments, into the potable water.
On Combi applications, circulators suitable for
DHW applications must be used.
Do not connect the water heater to any heating
systems or components that have been
previously used with non-potable water heaters.
If the system requires varying temperatures
for water—for example, hotter water for space
heating than for other uses—install a mixing
valve to temper the water and reduce the
potential for scalding.
Do not use the water heater for space heating
only.
Make sure circulator flow rate through the Water
Heater does not exceed 4 GPM.
Do not configure the system for DHW
Note
recirculation when it is configured to
run an air handler using the H2Air add-
on controller. DHW recirculation and
Navien H2Air configurations cannot be
used at the same time.
28
Installing the Water Heater
3.4.3 Adjusting the Recirculation
Parameters
Entering the R&D Information Menu
Follow the instructions below to enter the R&D
information menu.
1. On the Front panel, press the Power button to
turn off the water heater.
2. Enter the R&D information menu by pressing
the Up (+) button three times, the Down (-)
button three times, and then the Up (+) button
four more times.
3. In the R&D information menu, use the Up (+) or
Down (-) buttons to move to 2.PAR (Parameter
information mode), and then press the Info
button.
No. Mode
1
Technical Information
2
Parameter Information
4. To return to the previous menu (R&D
information menu), press the [Reset] button
once.
Items Name
Description
Set the
maximum
Pump Cycle
time for pump
12. P12
Interval
operation or
on-demand
operation.
Pump
Set the pump
14. P14
Sampling
cycle ON interval.
Time
Set the offset
temperature
to turn off the
Differential
preheating
15. P15
OFF Temp
operation
(function
disabled with
HotButton Kit).
Activate for use
Thermal
with NaviCirc
17. P17
Bypass Valve
recirculation
Enable
valve.
Display
Display