8. Six fi xing positions must be selected for ALL models
QM050RF, QM070RF, QM100RF, QM100RF, QM125RF and
QM150RF.
Common fi xing points for all heater sizes are shown, (Fig. 8).
Position the wall bracket on the location mark made
previously, drill the holes and fi t the wall fi xings best suited
to the application.
Secure the wall bracket using the correct quantity of screws
required per model, using the appropriate screw fi ttings.
Position the heater over the wall bracket and secure using a
screw at either side.
NOTE: DO NOT FULLY TIGHTEN THE SIDE FIXING
SCREWS UNTIL THE ENERGY CELLS ARE FULLY LOADED
TO ENSURE FULL WEIGHT IS ON THE FEET AND NOT ON
THE WALL FIXINGS.
CONNECTING MAINS SUPPLIES
WARNING - The electrical installation of this heater must be carried out by a suitably qualifi ed
or trained electrician, and be in strict accordance with current wiring Regulations.
The supply circuits to the heater must incorporate a double pole isolating switch having a
contact separation of at least 3mm.
The peak supply must be connected via a switched fused spur with a fuse rated suitably for
the appliances fl ex, the off -peak supply, via a 20A double pole switch. In both instances a
plug and socket arrangement MUST NOT be utilised.
• This heater must be earthed
• Do not locate the heater immediately above or below a fi xed electrical point i.e. socket
outlet.
This appliance is intended for installation to a single phase supply only and is not suitable for
connection to 3 phase supplies.
- 7 -
Fig. 8
9. The mains cable entry and terminal block will be visible
in the centre of the cavity at the right hand side. Insert the
mains cables through the cable gland at the bottom of the
heater in readiness for connection.
Cable Sizes
Peak mains cable 1.5mm2
Off -peak mains cable 2.5mm2
Single Supply mains cable 2.5mm2
IEC: 60227 IEC57 or CENELEC: H05V2V2-F

Mains Cable

Mains Cable
Only heat resistant ordinary polyvinyl
chloride sheathed fl exible cord should
be used, the following codes apply;
Fig. 9