ALIGNMENT
Alignment Precautions
Correct
alignment
requires
that
the
ambient
temperature
be
the
same
as
that
of
the
transceiver
and
test
equipment,
and
that
this
temperature
be
held
constant
between
20 and 30 °C (68 to 86 °F). When
the trans-
ceiver
is brought
into
the shop
from
hot or
cold
air it should
be allowed
some
time for
thermal equalization before alignment.
Alignments must only be made
with oscillator
shields
and
circuit
boards
firmly
affixed
in
place.
Also,
the
test
equipment
must
be
thoroughly warmed up before beginning.
Alignment
values
assume
an internal
DC
bus
voltage of 13.5V
DC.
Note:
Signal
levels
in dB referred
to in the
alignment
procedure
are
based
on
OdBu=0.5uV.
Test Equipment:
Spectrum
analyzer
covering
up
to
1300
MHz,
or
to
top
edge
of highest
frequency
band installed
Tracking
generator
covering
up
to
1300
MHz,
or
to
top
edge
of highest
frequency
band installed
RF
signal
generator
covering
up
to
1300
MHz,
or
to
top
edge
of highest
frequency
band
installed,
with
calibrated
output
and
modulation
RF
voltmeter
ranging
from
SmV
to
3Vrms,
with
5%
accuracy
to
1300
MHz,
or
to top
edge of highest frequency
band installed
Frequency
counter
with
0.1
ppm
accuracy
to
1300
MHz,
or
to
top
edge
of highest
fre-
quency band installed
DC
voltmeter
with
at
least
10
Megohms
impedance
In-line
wattmeter
accurate
to
1300
MHz,
or
to
top
edge
of
highest
frequency
band
installed
50-ohm
dummy
load,
non-reactive
to
1300
MHz,
or
to
top
edge
of highest
frequency
band installed,
30-watt capacity
FM Deviation meter and SINAD
meter
Sampling coupler "T"
AF
signal
generator
with
adjustable
output
from 0.5 to 100mV
AF millivoltmeter
Oscilloscope with 100 MHz bandwidth

Advertisement