Setting Addresses; System Connections - HP 59501A Operating And Service Manual

Hp-ib isolated d/a power supply programmer
Hide thumbs Also See for 59501A:
Table of Contents

Advertisement

type 57 micro-ribbon connector. One HP-IB cable is
supplied with each HP computer and calculator I/O card
package. Extra cables may be ordered separately.
HP-IB Cable Model No.
Cable Length
10631A
10631B
10631C
1m (3.3 ft.)
2m (6.6 ft.)
4m (13.2 ft.)
NOTE
The HP-IB connector supplied with this unit
contains metric fasteners (colored black). If
your HP-IB cable connector contains standard
mating screws (silver), make a conversion using
the hardware and instructions included in Metric
Conversion Kit (5060-0138).
2-19
The HP-IB cables use the same piggyback con¬
nector on both ends. Up to three connectors may be stacked
one upon another. As many as 15 instruments (including
the controller) may be connected to the same HP-IB.
2-20
System Connections
2-21
Figure 2-3 illustrates a controller (e. g., a 9825A
calculator) and a 59501A unit connected to the HP-IB. In
this case, the 98034A interface card provides HP-IB capa¬
bility for the 9825A calculator and is installed in any one
of the three slots in the rear of the calculator. The 98034A
card is equipped with the proper cable and connector to mate
with the HP-IB connector on the rear of the 59501 A. Note
that specific connections between the 59501 A's output ter¬
minals and the user's device (e.g. programmable power supply)
SIGNAL GROUND
24
12
P/0 TWISTED PAIR WITH II
23
11
P/0 TWISTED PAIR WITH 10
22
10
P/0 TWISTED PAIR WITH 9
P/0 TWISTED PAIR WITH 8
21
20
9
8
P/0 TWISTED PAIR WITH 7
19
7
P/0 TWISTED PAIR WITH 6
18
6
'
..fREN
17
5
LD108
16
4
Dior
15
3
0106
14
2
DIOS
13
1
¥r
SIGNAL GROUND
SHIELD
ATN
SRQ
IFC
NOAC
NRFO
DAV
EOI
0104
0103
0102
0101
note; type 57 MICRO-
RIBBON CX)(^CT0R
(AMPHENOL OR
CINCH)
** NOT PROCESSED BY 5950IA
HP-IB LOGIC LEVELS;GROUND TRUE.TTL C(»^PATIBLE.
INPUT LEVELS (FROM HP-IB): 1 « TRUE <0-8V
ei»FALSE>2,OV
OUTPUT LEVELS (TO HP-IB): 1 • TRUE «0VDC TO 0,4VDC
0-FALSE>'-r2.5VDC T0-f5V0C
Figure 2-2. HP-IB Connector
are not illustrated on Figure 2-3. These connections depend
upon the particular power supply being programmed'and
the type of control desired (output voltage or current).
The connections required to program various HP power
supplies are provided in Section 111, paragraph 3-45 through
3-52.
2-22
Setting Addresses
2-23
The I isten address for the 59501A is selected by
address switches on the rear of the unit. The switches are
factory set to the suggested listen address of & when the
unit is shipped from the factory. As shown in Figure 2-4,
there are seven address switches. The last two switches,
6 and 7 (XX), are ignored (have no affect). Switches 1,4,
and 5 are set to "0" and switches 2 and 3 are set to "1'' to
select a listen address of
Note that
is the suggested
listen address and is one of 31 listen address possibilities.
The address switch settings for each of the 31 listen address
possibilities are listen in Table 2-1.
2-2

Advertisement

Table of Contents
loading

Table of Contents