Honeywell BENDIX/KING KAP 140 Maintenance Manual page 87

Flight control system
Hide thumbs Also See for BENDIX/KING KAP 140:
Table of Contents

Advertisement

4.3.15 FLAPS INTERFACE TO THE KC 140
PIN
P1402 -- 45
P1402 -- 46
The FLAPS input on the KC 140 interfaces to the flaps motor in the aircraft. When the flaps are
in motion, the software in the KC 140 begins running trim in the aircraft to help prevent the pitch
servo from getting behind during configuration changes. If the flaps motor voltage is greater than
9 volts, the flaps motor is determined to be running (active). The voltage on the flaps input can be
viewed on the ANALOG INPUTS diagnostic page.
DIAGNOSTIC NAME
Flap Voltage
Revision 2, Dec/2002
CS:15574F02.IDU
BENDIX/KING
KAP 140
DESCRIPTION
FLAPS_+
FLAPS_--
SCALE FACTOR
1 V/V (>9 V or < --9V = active)
Page 4--13

Advertisement