NATIONAL ® COMFORT PRODUCTS HEATING & A/C EQUIPMENT Thru-the-Wall Comfort for all types of Multi-Family Construction Installation Guide Thru the Wall Condensing Unit This unit should be installed in an Outside Wall For Thru-The-Wall Installation Only! Read Installation Manual Prior To Starting The Installation. Please fill in the following information and file it for Series: future reference.
Specifications, Dimensional Drawings .......................... 18-19 Matched systems with Cased Coils ..........................20 Matched systems with Air Handlers ..........................20 Replacement Parts - NCP 1000 Series .......................... 21 Replacement Parts - NCP 3000 Series .......................... 22 Replacement Parts - NCP 4000 Series .......................... 23 Replacement Parts - NCP 5000 Series ..........................
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 Split System Condensing Unit Nomenclature 1000 NCP = Condensing Unit Refrigerant Capacity Series Generation Option Factory Use 4 = R410A 18 = 1.5 Ton 1000 A = Standard 24 = 2 Ton...
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 Safety Warnings! WARNING This appliance is not intended for use by those (including children) These instructions are intended as an aid to qualified, licensed service personnel for proper installation, adjustment and operation of with reduced physical, sensory or mental capabilities, or lack of this unit.
Installation Guide | Thru the Wall Condensing Units Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 NCP Series 1000/3000/4000/5000 Before You Start Make all electrical connections in accordance with the National Electrical Code and any pertinent local codes or ordinances. Use a separate branch electrical circuit for this unit.
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 Electrical - High Voltage Check for Clearances NOMINAL MINIMUM MAXIMUM VOLTAGE VOLTAGE VOLTAGE 208-230 High Voltage Power Supply Minimum 48" Vertical Clearance Between Units WARNING LIVE ELECTRICAL COMPONENTS! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components.
Coil Outdoor louvers provided by others must be approved by NCP to maintain unit performance and warranty. 7. If the unit is mounted behind a decorative grille, one or both of the following items must be done to eliminate recirculation of air to the unit: a.
Page 9
Installation Guide | Thru the Wall Condensing Units Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 NCP Series 1000/3000/4000/5000 7. Install the refrigerant lines using the following procedure (See Steps 1 Note: Always use refrigeration grade copper tubing that is internally thru 4.)
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 Step 3: Step 5a: Flux the copper tube and Using a liquid soap solution insert into the stub. Braze the joint. No flux is necessary if a low to zero-silver braze alloy is used.
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 Start Up b. If the evacuation is being performed on an installation where the condensing unit factory charge has been lost, the service valves should be opened. 1. Ensure that directions on page 6 through 10 have been completed. Check 2.
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 NATIONAL COMFORT PRODUCTS R-410A CHARGING CHART °F °F °F °F °F °F °F °F °F °F °F LIQUID PRESSURE AT SERVICE VALVE (psig) R-410A REQUIRED LIQUID LINE TEMPERATURE (°F)
Page 13
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 Ounces & Pounds of R410A Required for Line Sets Weight Tubing Size Ounces 3/8" - 3/4" 10.5 17.5 24.5 Pounds 3/8" - 3/4" 0.21875 0.4375 0.65625 0.875 1.09375 1.3125 1.53125...
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 Maintenance Checkout Procedures and Troubleshooting 1. Annually clean the inside of the unit to keep the weep holes in the base pan Checkout Procedures open to assure proper drainage of water from the unit.
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 Noise We design our unit as quiet as possible; please keep in mind when locating the unit that it does make noise. Use common precautions as you would for other mechanical appliances pertaining to noise.
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 IMPORTANT!!! BEFORE REMOVING A WARRANTY COMPRESSOR, PLEASE FILL OUT THE FOLLOWING AND CALL (800) 523-7138. REMOVAL OF COMPRESSOR WITHOUT FACTORY VERIFICATION CAN LEAD TO WARRANTY CREDIT BEING DENIED Incoming Voltage to Compressor at Contactor is:__________Volts Compressor Starting AMP Draw:__________ Ω...
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 208-230 VAC NOMINAL VOLTAGE 196 VAC MINIMUM VOLTAGE 244 VAC MAXIMUM VOLTAGE FUSED OR NON-FUSED DISCONNECT OPTIONAL C Y R BLACK BLACK WHITE (OPTIONAL) BLUE YELLOW BLACK BLACK WHITE...
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 1000 Series w/ matches up to 12.5 SEER2* 4 " 8 " All Units 208/230-1-60Hz Compressor Shipping Model weight (lbs) NCP4181000B-** 10.3 45.7 14.2 8 " 4 " NCP4241000B-** 11.7...
Page 19
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 4000 Series w/matches up to 12.5 SEER2* 30" 8 " All Units 208/230-1-60Hz Shipping Compressor Model Weight 4 " (lbs) 4 " NCP4184000B-** 10.3 45.7 14.7 NCP4244000B-** 11.7 59.5 16.4...
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 5000 Series Replacement Parts Guide Item Description NCP4185000B-** NCP4245000B-** NCP4305000B-** Contactor 142-62-082 142-62-082 142-62-082 Start/Run Capacitor 142-25-387 142-25-395 142-25-395 Low Pressure Switch 142-65-026 142-65-026 142-65-026 High Pressure Switch 142-65-029...
Page 25
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 539 Dunksferry Road | Bensalem, PA 19020 | 215-244-1400 | 1-800-523-7138 THRU-THE-WALL CONDENSING UNIT & HEAT PUMP LIMITED WARRANTY 1. National Comfort Products warrants to its customers that its product shall be free from defects in material and workmanship under normal use and regular service and maintenance as follows: COMPRESSORS: For five years from the date of original installation.
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 who use the Goods. National Comfort’s Goods are to be used in their recommended applications and all warning labels adhered to the Goods by National Comfort are to be left intact.
Page 27
Installation Guide | Thru the Wall Condensing Units NCP Series 1000/3000/4000/5000 Notes...
Page 28
National Comfort Products 539 Dunksferry Road | Bensalem, PA 19020-5908 (800) 523-7138 IM TTW CONDENSING UNITS 14299245 1/2024...