Monitor Performance; Specified Input Level Setting; Minimum Input Level Checks; Level Meter Calibration - Teac A-400 Service Manual

Stereo cassette deck
Table of Contents

Advertisement

4-1. MONITOR PERFORMANCE
NOTE
Place DOLBY
NR switch to OUT position for this monitor
circuit alignment procedure.
4-1-1. Specified Input Level Setting
1.
Connect an AF oscillator to the LINE IN jacks, through an
attenuator.
2. Connect
a VTVM_
between
the T.P. (test points) for
VR102/VR202
and ground on the REC/PB amplifier PC
board.
Load a TEAC MTT-505 test tape (blank) on the deck.
Adjust for -25dB on VTVM
(Specified RECORD control setting}
VTVM
—25dB(43.5mv)
OSCILLATOR
Place the deck in the PAUSE mode.
Apply a 400 Hz signal/—9 dB (274 mV) to the LINE IN jacks.
Turn the RECORD controls to obtain the reading of —25 dB
(43.5 mV) on the VTVM. Note the position of the RECORD
control as this is the specified
RECORD
control setting
referred to in subsequent procedures.
7. Connect the VTVM between the Dolby T.P. (test points) and
the ground on the REC/PB amplifier PC board.
8. Adjust VR102/VR202 to obtain 580 mV (2.5 dB).
oO or
oo
4-1-2. Minimum Input Level Checks
9. Turn the RECORD controls fully clockwise.
10.
Apply a 400 Hz test tone at minimum input level as listed
below to each input jack.
11. Check for (the specified value of) 580 mV (-2.5 dB) at the
Dolby test points using the VTVM.
INPUT Switch
Position
Input Jacks
Minimum Input Level
19 dB +3 dB (61.5 mV ~ 122 mV)
-67 dB +3 dB (0.244niV~0.488mV)
-35 dB +3 dB (9.75 mV ~ 19.4 mV)
LINE IN
LINE
Mic
MIC/DIN
DIN
MIC/DIN
4-1-3. Level Meter Calibration
"12. Set the INPUT Switch to the LINE position.
13. Set the AF oscillator for 400 Hz at —9 dB (274 mV) and set
RECORD controls to specified level. (same as set in 4-1-1)
14.
Adjust VR103/VR203
for +3 VU
(marked'with "O0") on
the level meter on the deck.
VTVM
—2.5dB (580mv)
OSCILLATOR
OodoLey TP |
400Hz
ATTENUATOR
RECORD}:
Max. Position
Minimum
Input
Level
DECK under TEST
(PAUSE mode)
.
Fig. 27 Test Condition for Minimum Input Level Checks
T~398
14
NOTE:
TP.
(for VRioz/VR202)
POOLBY TRI
400Hz
ATTENUATOR
VRio2/VR202,
DECK under TEST
(PAUSE made)
i)
Adjust for -2.5dB on VTVM
VTVM
-2.5dB (S80mv)
OSCILLATOR
vRioz/VReoz
DECK
under TEST
(PAUSE mode)
T397
OSCILLATOR
VRi03/VR203
+ 3vu
LEVEL
METER
|
RECORD control : Specified
Setting
DECK under TEST
{PAUSE mode)
TOROS
Fig. 28 Test Condition for Level Meter Calibration
400Hr
ATTENUATOR
For actual adjustment/test point locations, see page 21.