Electrical connections
Check that the power supply voltage shown on the rating plate
corresponds to the mains supply before proceeding to make any
electrical connections. If the unit is supplied ready-fitted with a
plug, it can be connected to any easily accessible socket installed
in compliance with the regulations in force.
If a fixed connection is required, the hood must be installed
exclusively by an electrician registered with the local electrical
company. The hood should be installed using an omnipolar switch
with contacts that open to at least 3 mm.
Fused switches can be used for this purpose (with cartridge fuses
that can be extracted from the fuse holder), as can automatic
circuit breakers and contactors which open to more than 3 mm.
We decline all responsibility for any problems or faults caused by
a failure to observe the above instructions.
Installing the socket directly above the hood or above the wall unit
mounted above the hood offers the following advantages:
1. The socket cannot be seen.
2. The unit can be disconnected whenever required by simply
taking out the plug.
Electrical connections
230 V - using fixed power supply line with plug.
(The unit should only be connected up by an authorized electri¬
cian).
Safety
warnings for
electrician
25