Microwave Ovens; Monitor Panel; To Read A Water Or Sewer Tank Level; To Read The Battery Voltage - Airstream Pottery Barn Special Edition 2024 Owner's Manual

Table of Contents

Advertisement

Complete operating instructions are located in your
owner's packet. If they should become misplaced, new
literature can be ordered directly from the manufacturer
or your Airstream dealer� The manufacturer also offers
a detailed service guide for your furnace�
WARNING
Carefully read all the manufacturer's instructions
prior to operating. NEVER store flammable
material next to the furnace or in close proximity
to the furnace exhaust outlet on the side if the
trailer.
NOTICE
If warranty service is required, use only a
service location recommended by the furnace
manufacturer or your Airstream dealer.

Microwave Ovens

Refer to the Certified Performance Checkout sheet,
included in your owner's packet, for manufacturer,
model, and serial number information�

Monitor Panel

The display is the only system component that is
accessed by the user� The display shown above is
located in a compartment, below the rear dinette seat�
All user input to the display is done using the buttons
along the bottom of the display� This information is
available on the main Multiplex touch screen and
communicates through the Airstream Smart RV Control
app�
NOTE
The following information is for use of the
SeeLevel II Monitor Panel. The Multiplex Systems
main control panel can also be used.
The display receives the information from the three
sender pads via a single, two-conductor wire, and
displays the level information in percent of full on a
three-digit, LED display� When the front panel button
for a particular tank is pressed, the display powers
up and displays the level for that tank� If the button is
pressed and released, the display will show the level
2024 Pottery Barn
for about 5 seconds and then shut down automatically�
If another button is pressed before the display shuts
down, then the new level will immediately be shown� If
the same button is pressed twice, the display will hold
on that tank and continue to show updated levels for
5 minutes before shutting off� This allows the user to
monitor the filling or draining of the tank. By pressing
two buttons at once, the diagnostic functions can be
accessed�
Sender pads are installed and stuck to the sides of the
holding tank� The sender scans the water level through
the tank wall using digital techniques programmed into
the sender microprocessor�

To Read a Water or Sewer Tank Level

1� Press the button corresponding to the tank to be
checked and release it, the display will show the
levels in percent on the LED display� If no other
button is pressed, then the display shuts off after
about 5 seconds�
2� If another button (including BATT) is pressed
before the 5 second time is up for the first button,
the display will immediately switch to show the new
level or voltage� The 5 second time-out is restarted
every time a button is pressed�
3� To continuously display a reading, press and
release the desired button, and then press the
same button a second time� When the button is
released, the display will be on hold mode, which
is indicated by the decimal point on the right hand
side turning on� While the display is in the hold
mode it will recheck the level once per second
so the user can watch the level change while the
tank is being filled or drained. The display will
automatically shut off after 5 minutes in hold mode�
To end the hold mode before the 5 minutes is up,
press any tank button, and the display will shut off�

To Read the Battery Voltage

1� Press the BATT button and release it, the display
will show the battery voltage on the LED display�
2� If no other button is pressed, then the display will
shut down after about 5 seconds� If the BATT
button is held down, the display will continuously
recheck the voltage and show the updated value�
The reading may flicker back and forth between
two values�
3� If another button is pressed before the 5 second
time is up for the BATT button, the display will
immediately switch to show the value for the new
button� The 5 second time-out is restarted every
time a button is pressed�