Sony TRINITRON KV-27EXR20 Service Manual page 3

Hide thumbs Also See for TRINITRON KV-27EXR20:
Table of Contents

Advertisement

KV-27EXR20/27EXR25
RM-Y104
RM-Y103
SAFETY CHECK-OUT
(US Model only)
1.
Check the area of your repair for unsoldered or poorly-soldered
connections. Check the entire board surface for solder splashes
and bridges.
2.
Check the interboard wiring to ensure that no wires are "pinched"
or contact high-wattage resistors.
7.
Check the condition of the monopole antenna (if any).
Make sure the end is not broken off, and has the plastic cap on it.
Point out the danger of impalement on a broken antenna to the
customer, and recommend the antenna's replacement.
9.
Check the antenna terminals, metal trim, "metallized" knobs,
screws, and all other exposed metal parts for AC leakage. Check
leakage as described below.
LEAKAGE
HOW TO FIND A GOOD EARTH GROUND
To Exposed Metal
Parts on Set
0.1 5uF
Bau.
me
voltmeter
(0.75V)
Earth Ground
Trouble Light
AC Outlet Box
Memeter
Cold-water Pipe
Fig. B. Checking for earth ground.
Bene; pee