Refrigeration Sequence of Operation (Continued)
The particular system design determines at
exactly what point (in the evaporator) the change
of state (i.e.: liquid to a gas) takes place. In all
cases, however, the refrigerant must be totally
evaporated (changed) to a gas before leaving the
evaporator coil.
The low pressure (suction) created by the
compressor causes the refrigerant to leave the
evaporator through the suction line as a cool low
pressure vapor. The refrigerant then returns to
the compressor, where the cycle is repeated.
Refrigeration Assembly
1. Compressor
2. Evaporator Coil Assembly
3. Condenser Coil Assembly
4. Capillary Tube
5. Compressor Overload
– 35 –