saFeTy WarNiNgs Read and understand tool labels and manual. Failure to follow WARNING warnings will result in DEATH or SERIOUS INJURY. Save These Instructions. Personal Protective equipment Use safety equipment. Always wear ANSI Z87+ safety glasses with permanently attached side shields. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for appropriate conditions.
Page 4
It is recommended that operators that are less experienced using pneumatic fastener driving tools choose a sequential mechanism until they become familiar with the tool and its operation. Please call Senco Customer Service to obtain an alternate trigger type in those tools that can be user modified to fit the application and/or level of operator experience.
Page 5
Operating Controls Do not use tool without danger label on tool. If label is missing, damaged or unreadable, contact your SENCO represen- tative to obtain a new label. Never use tool if safety element, trigger or springs have become inoperable, missing or damaged. Do not tamper with or remove safety element, trigger or springs.
Do not use tool if safety element or trigger sticks or binds. Squirt Senco pneumatic oil (5 to 10 drops) into the air inlet twice daily (depending on frequency of tool use). Other oils may damage O-rings and other tool parts.
Page 7
saFeTy WarNiNgs The employer, tool owner and tool operator: • are responsible for ensuring that the tools are kept in safe working order. • are responsible for ensuring that only qualified personnel shall repair the tool. • are responsible for ensuring that manufacturers tool maintenance instructions are available to personnel performing maintenance.
Push Tab on feeder shoe to release feeder from strip. Pull fastener strip out past sheet metal nail detainer. Do not load with workpiece contact (safety element) or trigger depressed. Use only genuine SENCO fasteners (see Fastener Specifications). actuation system: With a Contact-actuation (“Dual-action”) trigger, fasteners can be driven two ways:...
Wipe tool clean daily and inspect for wear. Use non-flammable cleaning solutions only if necessary–DO NOT sOaK Caution: Such solutions may damage O-rings and other tool parts. No routine oiling necessary. repairs other than those described here should be performed only by trained, qualified personnel. Contact seNCO for information at 1-800-543-4596.
Nail set above work surface Low air pressure Increase air pressure (No greater than 120 psi) Application too rigorous Consider alternate type of wood Rate of drive too fast Reduce drive rate Incorrect depth of drive Adjust setting Other problems Contact SENCO...
SENCO offers a full line of accessories for your SENCO tools, including: • Air Compressors • Hose • Couplers • Fittings • Safety Glasses • Pressure Gauges • Lubricants • Regulators • Filters • No Mar Pads Technical specifications...
KYOCERA-SENCO Industrial Tools, Inc. (“SENCO”) designs and constructs its products using the highest standards of material and workmanship. SENCO warrants to the original retail purchaser that the following products will be free from defects in material or workmanship for the warranty period...