Page 2
If by some chance breakdown or failure should occur within the warranty period and if it is clear that the cause of the problem rests with Orion, the item in question will be repaired without charge in accordance with the details below. Please note: This agreement is restricted to equipment used in Japan.
Page 3
Spec.No. KRF110-V-04E 2.Consumable parts / Periodic replacement parts (1) Consumable parts (Parts to be replaced depending on the state at the time of inspection) Name of Parts Parts Number Qty/ unit Inspection period Replacement criterion Filter element When damaged, or dirt cannot be 04041878010 ...
Page 4
The blade should be replaced soon if performance decreases or noise levels increase. * When vanes are replaced, replace bearing at the same time. Use ORION specified bearings that are lubricated with special grease. * Use the maintenance kit for replacement parts.
Page 5
Spec.No. KRF110-V-04E 3. Specifications Model KRF110-V-04 Frequency Hz Designed capacity L/min *1 1850 2200 Continuous operative 60or less kPa vacuum * 2 Ultimate vacuum *3 90or more kPa Diameter of piping Rc1 1/4 connection Phase・output・pole Three-phase・3.7kW・6P Frame no. / heat 132S・B...
Page 6
Spec.No. KRF110-V-04E *1 Designed capacity: It is the theoretical value calculated from capacity. Please use the pressure-flow rate diagram for the actual flow rate. *2 Continuous operative vacuum: Operative range of vacuum. Install the gauge and controller to the pump or the piping, and use the Dry Pump at the continuous operative vacuum or less.
Spec.No. KRF110-V-04E EC DECLARATION OF CONFORMITY −6− ...
Page 8
Spec.No. KRF110-V-04E 4. Precautions Observe precautions, and operate the product within specifications. Read the instruction manual prior to installation, operation, maintenance and inspection of the product. Especially pay attention to safety. The vanes may get damaged if the residual pressure reverses the rotation when the pump stops.
Page 10
A and B. Earth terminal Power terminal Fixing screw M6 Fixing screw 6-M5 Detail of terminal box A:Rc1・1/4 B:Rc1・1/4 赤針以上使用禁止 DRY-PUMP Model KRF110-V-01 Ser No. ****** ORION MACHINERY CO.,LTD. 246 KOTAKA,SUZAKA-SHI, NAGANO-KEN 382-8502 JAPAN 4-φ12 (394) (950)