Installation Guide
VLT® Control Panel LCP 23
VLT® AutomationDrive FC 360
1 Introduction and Installation
1.1 Description
This installation guide explains how to install the VLT® Control Panel LCP 23 for VLT® AutomationDrive FC 360.
1.2 Item Supplied
VLT® Control Panel LCP 23 (code number: 132B0801).
1.3 Safety Precautions
Only qualified personnel are allowed to install the LCP 23 described in this installation guide.
For important information about safety precautions for installation, refer to the drive's operating guide.
DISCHARGE TIME
The drive contains DC-link capacitors, which can remain charged even when the drive is not powered. High voltage can be
present even when the warning indicator lights are off.
Failure to wait the specified time after power has been removed before performing service or repair work could result in death or
serious injury.
-
Stop the motor.
-
Disconnect AC mains, permanent magnet type motors, and remote DC-link supplies, including battery back-ups, UPS, and
DC-link connections to other drives.
-
Wait for the capacitors to discharge fully. The minimum waiting time is specified in the table Discharge time and is also visible
on the nameplate on top of the drive.
-
Before performing any service or repair work, use an appropriate voltage measuring device to make sure that the capacitors
are fully discharged.
Table 1: Discharge Time for FC 360
Voltage [V]
Enclosure size
3x400
J1, J2, and J3
3x400
J4, J5, J6, and J7
3x400
J8 and J9
1.4 Mounting the LCP 23
Procedure
1.
Position the bottom of LCP 23 in the drive, see
When mounting the LCP 23, do not push or press too hard!
-
If it is not possible to mount the LCP 23 in one easy operation directly on the drive, try to insert LCP 23 before
mounting the terminal cover. When the terminal cover is removed and the drive is powered, do not touch the pow-
er terminals.
Danfoss A/S © 2022.11
W A R N I N G
Power range [kW (hp)]
NO
0.37–7.5 (0.5–10)
11–90 (15–125)
11–75 (15–100)
110–315 (150–450)
90–250 (125–350)
Illustration
1.
C A U T I O N
Minimum waiting time (minutes)
HO
AN425137357164en-000101 / 130R1273 | 1
4
15
20

Advertisement

loading

Summary of Contents for Danfoss VLT Control Panel LCP 23

  • Page 1 If it is not possible to mount the LCP 23 in one easy operation directly on the drive, try to insert LCP 23 before mounting the terminal cover. When the terminal cover is removed and the drive is powered, do not touch the pow- er terminals. Danfoss A/S © 2022.11 AN425137357164en-000101 / 130R1273 | 1...
  • Page 2 Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.