Graco A Series Instructions-Parts List Manual page 5

Power supply module , dispensing module , fluid meter
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

RECOMMENDED
INSTALLATION
DATA FOR MODULAR
FLUID COMMANDER
INVENTORY
CONTROL SYSTEMS
(For fluids
other
than
lubricants,
contact
Grace
Application
Engineering
Department)
TYPE
OF
SERVICE
LENGTH
RECOMMENDED
*RECOMMENDED
SIZE
REQUIRED
OF RUN
PUMP
SIZE
&TYPE
PLUMBING
ADDITIONAL
EQUIPMENT
Feet (Meters)
Motor
Oil
And
Automatic
Transmission
Fluid
90 Gear Lube
140 Gear Lube
Air
SUPPlY
50 (15) maximum
1:l ratio
1 or2
100 (30) maximum
1 :l ratio
3 or 4
200 (60) maximum
5:l ratio
1 or2
Fluid supply line
200-500 (60-150)
5:l ratio
3 or 4
Pressure Relief Kit
500 (150) and over
1O:l ratio
1 or2
(No. 207-221 i
100 (30) maximum
5:l or 1O:l ratio
1 or2
200 (60) maximum
10: 1 ratio
3 or 4
50 (15) maximum
1O:l ratio
1 or2
100 (30) maximum
1O:l ratio
3 or 4
Compressor
5
RECOMMENDED
EQUIPMENT
main lines
Master air valve (bleed type)
Stub lines
off main
6
Air control
valve (204-886)
1.
5/8 in. OD annealed
steel tubing
of minimum
0.035 in. wall - use flareless fittings.
2.
l/2
in. standard
pipe -use heavy malleable
iron fittings.
3.
7/8 in. OD annealed
steel tubing
of minimum
0.035 in. wall - use flareless fittings.
4.
3/4 in. standard
pipe - use heavy malleable
iron fittings.
5.
l/2
in. OD type "L"
soft copper tubing
or l/2
in. galvanized
pipe.
6.
3/8 in. or l/2
in. OD type "L"
soft copper tubing
or 3/8 in. or l/2
in. galvanized
pipe.
307-362