Tray Advance Unreliably?.13; Owner'smaintenance; Cleaning The Built-In Tape Deck.13; Cleaning The Built-In Viewing Screen.13 - Kodak 220 Manual

Hide thumbs Also See for 220:
Table of Contents

Advertisement

Tray Advance Unreliably?
Compact cassette slide-advance sig¬
nals and program-pause signals con¬
forming with spacing, frequency, du¬
ration, and level characteristics listed
under "Specifications" on page 17 will
operate the AudioViewer/Projector
dependably. Signals not conforming
to these specifications may result in
undependable operation. For example,
slide-advance signals of the correct
frequency (1000 Hz) but of the wrong
duration (other than 0.07 sec.) may
result in erratic slide-tray advance.
(Tapes made in conformance with
ANSI Standard PH7.4-1975 will oper¬
ate this machine dependably.)
Tapes recorded with earlier models
of the
EKTAGRAPHIC
Audio Viewer
or
EKTAGRAPHIC AudioViewerl
Projector will operate an
EKTAGRAPHIC
Audio Viewer/
Projector, Models 220, 270, 470, or
570AF dependably, and vice versa.
OWNER'S
MAINTENANCE
Cleaning the Built-In Tape Deck
If possible, clean the built-in tape
deck after every program. Cleaning
the tape deck takes only a few min¬
utes and helps prevent buildup of
oxide from tapes and loss of sound
fidelity.
1. Unplug the power cord!
2. Press the tape stop/eject button to
open the cassette well. Then par¬
tially close the cassette well door
to position the heads of the tape
deck for more convenient access
for cleaning.
3. Press and hold in the tape play
button to keep the tape heads
forward.
4. Rub the capstan, tape-guide path,
and metallic heads with a cotton
swab moistened with head-clean¬
ing solution or isopropyl alcohol.
5.
Do not touch the heads with any
metallic object,
A head-cleaning
cassette (available at radio-supply
stores) can be used occasionally,
but a swab dipped in isopropyl
alcohol is preferred.
Clean the tape deck often to prevent buildup of
oxide on the heads and loss of sound fidelity.
Head-Cleaning Cassette
Cleaning the Built-In Viewing
Screen
Use a soft, damp cloth to clean the
built-in viewing screen. Do not use
lens-cleaning solutions or tissues con¬
taining silicone.
The optics and mirrors inside the
AudioViewer/Projector should be
cleaned only by a qualified techni¬
cian, such as those at a Kodak Ser¬
vice Center (addresses on back cover).
Partial disassembly of the Audio¬
Viewer/Projector is required for this
service.
Adjusting the Position of the Image
on the Built-In Viewing Screen
All
KODAK EKTAGRAPHIC
Audio-
Viewer/Projectors have been designed
to let the owner maintain, and make
minor adjustments to, the machine as
necessary.
The front mirrors have to be read¬
justed when the image on the built-in
screen is not in perfect alignment.
Adjustments are made with the
screws located on the front-projection
door. Be sure the image-magnifying
lever is located in its "up" position,
for normal (unmagnified) viewing
of images; then close the front-
projection door.
Vertical Image Alignment
1. Insert a slide into the gate of the
AudioViewer/Projector.
2. Turn the lower left screw to center
the image vertically. (The front-
projection door may need to be
opened slightly to reveal the
screw.)
Horizontal Image Alignment
1. Insert a slide into the gate of the
AudioViewer/Projector.
2. Turn the upper right screw on the
front-projection door to center the
image from side-to-side.
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

270470570afEktagraphic 220Ektagraphic 270Ektagraphic 470 ... Show all

Table of Contents