Product Description; Product Design - Vaillant flexoTHERM exclusive Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Max. refrigerant circuit pressure: 4.60 MPa (g) (46.00 bar
(g))
Waiting period: 5 minutes (after the first occurrence)
Waiting period: 30 minutes
(after the second and every further occurrence)
The fault counter is reset if both of the following conditions
are met:
Heat requirement without switching off prematurely
60 minutes of uninterrupted operation
3.3.7
Hot gas thermostat in the refrigerant circuit
The hot gas thermostat shuts down the heat pump if the tem-
perature in the refrigerant circuit is too high. Following a wait-
ing period, the heat pump attempts to start once more. After
three failed start attempts in succession, a fault message is
displayed.
Max. refrigerant circuit temperature: 135 ℃
Waiting period: 5 minutes (after the first occurrence)
Waiting period: 30 minutes
(after the second and every further occurrence)
The fault counter is reset if both of the following conditions
are met:
Heat requirement without switching off prematurely
60 minutes of uninterrupted operation
3.3.8
Safety cut-out (SCO) in the heating circuit
If the temperature in the heating circuit of the internal elec-
tric back-up heater exceeds the maximum temperature, the
safety cut-out shuts down the electric back-up heater as a
securing measure. Following a waiting period, another at-
tempt is made to start the electric back-up heater. A fault
message is displayed that can only be reset by pressing the
Reset button or by switching the heat pump off and on again.
Max. heating circuit temperature: 85 ℃
10
4

Product description

4.1

Product design

4.1.1
Front view, open
4
3
1
Electronics box
2
Control panel
12
11
10
9
8
7
6
1
Electric back-up heater
2
Condenser
3
Heating pump
4
Electronic expansion
valve EVI (intermediate
circuit injection)
5
Heating circuit
filling/draining cock
6
Data plate
Installation and maintenance instructions 0020213394_05
1
2
3
Heating/cylinder char-
ging diverter valve
4
4-port valve
1
2
3
4
5
7
Carrying straps for
transport
8
Compressor
9
Electronic expansion
valve
10
Brine circuit
filling/draining cock
11
Brine circuit pump
12
Evaporator (not visible)