62
R E P A I R S

7.11 Exchanging the coffee capsule seal

Before changing the illumination components repairing operations 7.3.2 to 7.3.4 and
7.3.6 have to be completed.
Service manual ZN100 V 6.0
1. Please ensure that the connecting
tube leading to the hot water valve is
not subject to excess tension. If this is
the case, loosen the tube connection
at the hot water solenoid valve by pul-
ling out the retaining clip.
2. Remove the circlip at the front axis of
the brewing unit closing mechanism.
3. Pull the front axis completely out of
the connecting rods.
4. Remove the front of the brewing unit.
5. Loosen the 2 screws on the capsule
retain and lever these out of the bre-
wing unit.