A: Cut the pipe
Confirm the pipe length according to the distance of indoor unit
and outdoor unit.
Cut the required pipe with pipe cutter.
pipe
B: Remove the burrs
Remove the burrs with shaper and prevent the burrs from getting
into the pipe.
C: Put on suitable insulating pipe
D: Put on the union nut
Remove the union nut on the indoor connection pipe and outdoor
valve; install the union nut on the pipe.
E: Expand the port
Expand the port with expander.
pipe cutter
downwards
union pipe
pipe
expander
49