Shallow well jet pump

Advertisement

INSTALLATION
/ OPERATION
INSTALLATION
SEARS jet pumps
should
be used
with
Captive
Air® Tanks
(See
Figure
5).
TO SERVICE
PRIMING PLUG
PRESSURE
t JET
BUIL_I
N
pLASTIC
pIPE*
PLASlqC
PiPE
PUMP
TO T ANK
SIDE VIEW
ta.kfiffingskiL
FIGURE
5
For mounting
pump
to tank, purchase
tank fittings
Kit No. 2788.
SEARS Captive
Air* Tanks are pre-charged
at the factory.
Check
the
tank Owners
Manual
to find if air charge
needs
adjustment.
Model
390.251483
and Model
390.251883
require
40 pounds
for proper
operation.
The jet pump
can also be mounted
on standard
horizontal
tanks.
A
mounting
kit with
an AVC is furnished
with
tank.
(Figure
6).
Instructions
are also included.
TO SERVICE
_
PRIMING
PLUG _._
SHALLOW
WELL JET
PRESSURE
/
/BUILT.IN
CHECK
SWITCH
__F_L_vBOAU_
LVEI/4, PLASTIC
pipE *
,_%u. ,%omo_
SIDE
o0--T
v, w
VO4.UMECONTROL
"Not included
with
tank flnlnqs
kit,
FIGURE
6
The installation,
operation,
and care of your Hydroglass*
Pump is
very similar
to cast iron pumps.
We ask, however,
that you keep
the following
points
in mind.
NOTICE:
Use Teflon tape supplied
with
the pump
for making
all
threaded
connections
to the pump.
DO NOT USE PIPE JOINT
COMPOUND.
1.
Wrap
1-1/2 to 2 turns of Teflon
tape to all male
pipe
threads
being
attached
to the pump.
This will insure
leakproof
connec-
tions.
Do not overtighten
threaded
fittings
in the plastic pump.
If leaks do occur,
remove
the fitting,
replace
the Teflon
tape,
and rewrap
with
1-1/2 to 2 turns of Teflon
tape and remake
the
connection.
2.
independently
support
all piping
connected
to the Hydrogfass
_
Pump,
/
/
\
//
END VIEW
FIGURE
7
OPERATION
Priming
the
Pump
IA
j NEVER
run
pump
dry.
Running
pump
without
CAUTION
water
may overheat
unit, damaging
seals and possibly
burning
per-
sons handling
pump.
L_'WARNIN_G_]
NEVERrun pump against closed discharge. To
do so can bod water
inside
pump,
causing
hazardous
pressure
in
unit and possibly
scalding
persons
handling
pump.
1.
Remove
priming
plug.
Fill pump
with
water.
Replace
priming
plug. If a priming
tee and plug have been installed
for a long hor-
izontal
run, be sure
this line
is filled and the plug
replaced.
(Figure
2, Page 4).
2.
Start the pump.
Water
will be pumped
in a few minutes;
the
time
depending
upon
the depth
to water
and length
of hori÷
zontal run. If pump
does not prime,
check
for a possible
leak in
the suction
line.
Reprime.
Check
to be sure suction
lift - dis-
tance from pumping
water
level to pump
- does not exceed
20
feet. See °Piping
in the Well" on Page 4.
6