CONDENSED WATER DRAINAGE
DRAIN WANRN
To achieve maximum cooling efficiency, the airconditioner is designed
to splash the condensation water on the condenser coil.
In order to avoid the splashing sound, an external drain can be provided
by using the following procedure. T his may however cause a small loss of
performance.
1. Remove the cabinet screws from rear side.
2. Slide out the chassis from the cabinet.
3 . Remove the rubber plug from the body base plate.
4 . Install the drain pan at the corner of the cabinet.
5. Connect the drain hose to the outlet on the bottom of the drain pan.
6 . Slide the chassis into its original place in the cabinet.
1. Remove the cabinet screw from rear side. 4. Install the drain pan at corner of cabinet.
2. Slide out the chassis from the cabinet.
3. Remove the rubber plug from the
body base plate .
4
5. Connect the drain hose with the drain pan.
External View
Note: Drain hose or tubing can be purchased
locally to satisfy your particular needs.
6. Slide off the chassis back into the cabinet