2. Adjusting Room Temperature
A. Press the "▲MIN." or "▼HOUR" button. ˚F or ˚C will start to flash.
NOTE: The"▲MIN." or "▼HOUR" button will change the temperature in increment of 1˚C (2˚F).
B. Press the "▲MIN." or "▼HOUR" button as required. Room temperature can be set from 10˚C (50˚F) to 32°C
(90˚F). (Initial setting : 13˚C (56˚F))
NOTE: Desired temperature setting will be displayed on the digital indicator when you set the room
temperature.
C. When room temperature reaches the selected setting, heater will automatically shift to "MED" or "LOW"
burning mode to maintain the desired temperature.
When room temperature exceeds the selected setting by approx. 2˚C (4˚F), the heater will automatically shut
off. As room temperature drops, the heater will automatically re-start to maintain the desired temperature.
POWER SAVER OPERATION
The Power Saver mode reduces the frequency of ignition actions, to save electric consumption.
Press the POWER SAVER (DAY SELECT) button "ON" while in operation to start the operation of the "POWER
SAVER". "POWER SAVER" sign will be shown on the digital indicator.
When the room temperature exceeds the selected setting by approximately 6˚C (10˚F), the heater will
automatically shut off. As the room temperature becomes lower than the selected setting, the heater will
automatically re-start to maintain the desired temperature.
9
Approx. +2˚C
Approx. +1˚C
SET
TEMP.
High
Medium
Approx. +6˚C
Approx. +1˚C
SET
TEMP.
High
Medium
Low
Off
Low
Off
Re-lgnition
Re-lgnition