HEAD REPLACEMENT
NOTE:
Heads
can
be
replaced
individually
or
as
a complete
assembly.
Azimuth
adjustment
(electronic)
is not
to be performed
until
all
mechanical
alignments
have
been
performed.
After
replacing
the
heads,
proceed
to
the
next
page
for
mechanical
alignment.
CAUTION:
All
power
must
be
removed
from
the
unit
when
replacing
heads
to
prevent
transient
pulses
from
passing
through
the
heads.
These
may
cause
strong
magnetization
of
the
head
material
or
damage
the delicate
winding.
HEAD ASSEMBLY
REPLACEMENT
~ Remove
the head housing
cover by loosening
two hex screws
on top of cover.
~ Remove
the four mounting
screws
indicated
by
the arrows in the. diagram.
~ Slide
the assy out
from
the plug.
- Fit
the original
shielding
plate onto
the new
head assy.
- Slide
the new
assembly onto
the unit
and se-
cure
the
four screws.
- Proceed
to the next
page
for mechanical
align-
ment
procedures.
INDIVIDUAL
HEAD REPLACEMENT
NOTE:
All of the heads
are
individually
mounted
on
the
top
base
plates
of
head
assembly
for easy accessibility
and
servicing.
-
Remove
head
housing
cover
to
expose
head
assy.
~
To
replace
a single
head,
a
special
2mm
nut
driver
is
required.
~- Remove
the two nuts
on the defective
head
through
the,
access
hole
provided
to
release
the head
from the mounting
plate.
- Note the position
of the head's wires
on the
circuit
board
and unsolder
the defective
head.
-
Using
figure
for
reference,
connect
the
new
head
to the circuit
board.
-
Head
installation
mounting
provides
for
either
left
or
right
positioning.
-
Determine
the
proper
position
by
adjusting
the
nuts
to obtain
a 90° angle between
the tape
and the head.
~
Proceed
to
the
next
page
for
mechanical
align—
ment
procedures.