Hoshizaki KM-420MWJ Service Manual page 50

Modular crescent cuber
Hide thumbs Also See for KM-420MWJ:
Table of Contents

Advertisement

Low Ice Production - Possible Cause
1. Evaporator
2. Float Switch
See "II.E. Float Switch Check
and Cleaning"
3. Inlet Water Valve
4. Hot Gas Valve
5. Condenser
6. Control Board
See "II.C. Control Board Check"
7. Refrigerant Charge
8. Thermostatic Expansion Valve
9. Compressor
10. Pump Motor
11. Liquid Line Valve
12. Headmaster (C.P.R.)
(remote models)
13. Splash Guard
Long Freeze Cycle
a) Scaled up, dirty.
a) Scaled up, dirty.
b) Float sticking.
c) Defective switch.
a) Leaking by.
a) Erratic or open.
a) Clogged.
a) Float switch connection loose (K5).
b) Defective.
a) Low.
a) Bulb loose.
b) Defective.
a) Inefficient or off.
a) RPM too slow.
a) Erratic or restricted.
a) Not bypassing.
a) Out of place.
b) Missing or damaged.
50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents