3.2.2 Adjusting the DHW Indirect Supply
Temperature
To adjust the water temperature:
1. Press the Mode button twice. The DHW mode icon turns on.
2. Press + (Up) or – (Down) buttons until the desired temperature
appears on the display.
You can adjust the temperature while the display is flashing. Once
the display stops flashing, the temperature setting is stored.
Take note of the original DHW temperature in case
Note
you want to restore it to the default.
The default DHW temperature range is 104°F (40°C,
Absolute MIN) to 180°F (82°C, Absolute MAX).
You can adjust the temperature range in the
parameter settings menu.
The boiler will retain your settings during a power
outage.

3.3 Viewing Basic Information

To view information about the boiler, press the Mode button three
times. "INFO" will appear on the display.
Press the + or – buttons to switch between the information types.
Display
Space heating supply water
temperature (°F)
Pri
psi
Space heating return water
temperature (°F)
Pri
psi
Outdoor air temperature (°F)
(from Outdoor Temperature Sensor)
Pri
psi
Outdoor reset curve
-: Not in use.
1: Finned tube baseboard
2: FAN coil
3: Cast iron baseboard
4: Low mass radiant
Pri
psi
5: High mass radiant
6: Radiator
7: Custom (set by installer)
Description
Operating the Boiler
9