Download Print this page

Mitsubishi Electric CITY MULTI PLFY-EP NEMU-E1 Series Operation Manual page 11

Air-conditioners for building application

Advertisement

Available languages

Available languages

3. Operation (For Wired Remote controller)
3.6. 3D i-see Sensor setting
3.6.1 3D i-see Sensor setting
Main
Main menu
Operation
ON
RETURN SELECT
MENU
OFF
HOLD
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
ON
RETURN SELECT
MENU
OFF
HOLD
Comfort
Manual vane angle
3D i-See sensor
Setting display: SELECT
Cursor
ON
RETURN SELECT
MENU
OFF
HOLD
3D i-See sensor
Air distribution
Energy saving option
Seasonal airflow
Setting display: SELECT
Cursor
ON
RETURN SELECT
MENU
OFF
HOLD
1 Select "Operation" from the Main
menu, and press the [SELECT/
HOLD] button.
2 Select "Comfort" from the
Operation menu, and press the
[SELECT/HOLD] button.
3 Select "3D i-See sensor" with the
[F1] or [F2] button, and press the
[SELECT/HOLD] button.
4 Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT/HOLD] button.
• Air distribution
Select the airflow direction control
method when the airflow direction
is set to "Auto".
• Energy saving option
Operates the energy-save mode
according to whether persons are
detected in the room by the 3D
i-see Sensor.
• Seasonal airflow
When the thermostat turns off, the
fan and the vanes operate accord-
ing to the control settings.
3.6.2 Air distribution
Air distribution
M-NET address
Identify unit Check button
Input display: SELECT
Address
Check
ON
RETURN SELECT
MENU
OFF
HOLD
Air distribution
M-NET address
Auto vane
Direct/Indirect
Direct/Indirect setting
Select: SELECT
Cur.
ON
RETURN SELECT
MENU
OFF
HOLD
Direct
Cooling
horizontal → swing
Heating
keep downward
Direct/Indirect setting
:
Direct
: Indirect
: Indirect
: Direct
Select: SELECT
Angle
Outlet
ON
RETURN SELECT
MENU
OFF
HOLD
1 Select the M-NET address for the
units to whose vanes are to be
fixed, with the [F2] or [F3] button,
and press the [SELECT/HOLD]
button.
Press the [F4] button to confirm the
unit.
The vane of only the target indoor
unit is pointing downward.
2 Select the menu with the [F4] but-
ton.
Default → Area → Direct/Indirect
→ Default...
Default: The vanes move the same
as during normal operation.
During cooling mode, all of the
vanes move to the horizontal air-
flow direction.
During heating mode, all of the
vanes move to the down airflow
direction.
Area: The vanes move to the down
airflow direction toward areas with
a high floor temperature during
cooling mode and toward areas
with a low floor temperature dur-
ing heating mode. Otherwise,
the vanes move to the horizontal
airflow direction.
Direct/Indirect: The vanes auto-
matically move relative to the areas
where persons are detected.
The vanes operate as indicated in
the following table.
Vane setting
Indirect
keep horizontal
downward → horizontal
3 When Direct/Indirect is selected,
set each air outlet.
Select the air outlet with the [F1] or
[F2] button, and change the setting
with the [F4] button.
After changing the settings for all of
the air outlets, press the [SELECT/
HOLD] button to save the settings.
* In order to enable this function,
the airflow direction must be set
to "Auto".
10
en

Advertisement

loading