WAGNER Cobra 40-10 Translation Of The Original Operating Manual page 34

High-pressure double diaphragm pumps
Table of Contents

Advertisement

Operating manual High-pressure double diaphragm pumps Cobra 40-10; Cobra 40-25
6   Assembly and Commissioning
3
B_06818
Earthing schema (example)
Pos
Part / workstation
1
Conveyor
2
Work piece
3
Pump
4
Product tank
5
Spraying stand
Alternative: Spray booth
6
Floor, static dissipative
Safe operation of the pump is only guaranteed with a grounding connection. connect all
grounding cables using a short and direct route,
B_01214
1. Screw on grounding cable with eyelet.
2. Clamp the grounding cable clip to a grounding connection on site.
3. Ground the product tank to an on-site grounding connection.
34
4
6
2
5
R max < 1 MΩ
Cable cross section
16 mm²; AWG6
--
4 mm²; AWG12
6 mm²; AWG10
16 mm²; AWG6
--
Order number 2340851 | Edition 05/2022
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cobra 40-25

Table of Contents