  • Page 1 NOTICE D’INSTALLATION INSTALLATION INSTRUCTION MANUALE D’INSTALLAZIONE (Etiquette signalétique) KH2ZPC MODULE 2 ZONES PLANCHER 2-ZONE FLOOR MODULE MODULO A 2 ZONE PER IMPIANTO A PAVIMENTO Juin 2010 BA 10 11 465 - F.GB.I - 02...
  • Page 2: Table Of Contents

    MARKING This product marked conforms to the essential requirements of the Directives: - Low voltage no. 2006/95/EC. - Electromagnetic Compatibility no. 2004/108/EC. CONTENTS 1 - General ..........2 2 - Presentation .
  • Page 3: Presentation

    2 - PRESENTATION 2.1 - DESCRIPTION 1 - Housing 10 - Circulator terminal strip, zone 1 2 - Mixing cylinder 11 - Circulator terminal strip, zone 2 3 - Automatic air vent valve 12 - Control board, zone 1 4 - Motorised, 3-way valve, zone 1 13 - Control board, zone 2 5 - Motorised, 3-way valve, zone 2 14 - Outlet water sensor, zone 1...
  • Page 4: Installation

    3 - INSTALLATION • Protection rating of the module: IP 31. • The module must be installed in a sheltered location. • Remove the module's front panel (6 screws on the sides). • Secure the module to the wall. See the position of the 4 mounting holes in paragraph 2.2. 4 - CONNECTIONS 4.1 - HYDRAULIC CONNECTION •...
  • Page 5 Control box With built-in ambient temperature sensor. To be installed in zone 1. 2-ZONE FLOOR MODULE A BUS Board, zone 2 Board, zone 1 Heating board HEATING MODULE Water Water temperature, temperature, zone 1 zone 2 Possible accessory Ambient Ambient 70250065 temperature, temperature,...
  • Page 6: Start-Up

    4.2.3 - ZONE BOARD CONNECTION DETAIL Water temperature sensor Valve contact input (floor outgoing line) Pump control Zone ambient temperature sensor Zone addressing micro-switch 230 Vac Valve control 4.2.4 - CABLE ROUTING 230 V power supply BUS A Zone ambient sensor(s) P 5 - START-UP IMPORTANT NOTE...
  • Page 7: Maintenance Instructions

    5.3 - OPERATION • Check circulator operation in the generator and the operation of the 2 circulators of the module. Adapt the speed of the circulators in order to respect the flow rates. For the generator, refer to the corresponding installation manual. Note: When the system is off, operation can be forced by changing the parameterization: - of zone 1 (accelerator on and control valve open) with parameter 65,...
  • Page 8: Electrical Diagram

    Control valve, zone 2 Temperature ambiance sensor (zone 2) Circulator, zone 1 Circulator, zone 2 Circuit breaker, zone 1 Circuit breaker, zone 2 ELECTRICAL DIAGRAM - KH2ZPC 10 05 807 - 03 Power supply 230V / 1 / 50 Water probe Water probe...
  • Page 11 REMARQUE : Ce symbole et ce système de recyclage s'appliquent uniquement aux pays de l’UE. Ils ne s'appliquent pas aux pays des autres régions du monde. NOTE: This symbol mark and recycle system are applied only to EU countries and not applied to the countries in the other area of the world.
  • Page 12 157, Avenue Charles Floquet 93158 Le Blanc-Mesnil - Cedex Téléphone : + 33 (0)1 45 91 56 00 Télécopie : + 33 (0)1 45 91 59 50 Par souci d'amélioration constante, nos produits peuvent être modifiés sans préavis. Due to our policy of continuous development, our products are liable to S A au capital de 43 214 640 modification without notice.