Start-Up Amps Maintenance Contract; Training; Sound Pressure Level - Trane Airfinity XL IC140 Manual

Large packaged rooftop units 140 to 270 kw r410a – r454b refrigerant
Table of Contents

Advertisement

Maintenance Contract
It is strongly recommended that you sign a maintenance
contract with your local Service Agency. This contract
provides regular maintenance of your installation by
Sound power levels
a specialist in our equipment. Regular maintenance
ensures that any malfunction is detected and corrected
in good time and minimizes the possibility that serious
Discharge
damage will occur. Finally, regular maintenance
ensures the maximum operating life of your equipment.
Measurement conditions:
We would remind you that failure to respect these
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
installation and maintenance instructions may result in
long) fixed to its discharge opening.
immediate cancellation of the warranty.
Fan
Unit
speed
Storage
1
FWD 08
2
Take precautions to prevent condensate formation
3
inside the unit's electrical components and motors
1
when:
FWD 10
2
3
a. The unit is stored before it is installed; or,
1
FWD 12
2
b. The unit is set on the roof curb and temporary
3
auxiliary heat is provided in the building.
1
FWD 14
2
Isolate all side panel service entrances and base pan
3
openings (e.g., conduit holes, Supply Air and Return Air
1
openings, and flue openings) to minimize ambient air
FWD 20
2
3
from entering the unit until it is ready for start-up.
Do not use the unit's heater as temporary heat without
Intake
completing the start-up procedures detailed under "Unit
Start-Up".
Measurement conditions:
Measurements taken at the horizontal air intake.
• Units charged with refrigerant should not be stored
where temperatures exceed 68°C.
Fan
• At least every three months, attach a gauge and
Unit
speed
manually check the pressure in the refrigerant circuit.
1
FWD 08
2
• If the refrigerant pressure is below 13 bar (R410A) /
3
12.5 bar (R454B) at 20°C or 10 bar (R410A) / 9.5 bar
1
(R454B) at 10°C, call a qualified service organization or
FWD 10
2
3
Trane Sales Office.
1
FWD 12
2
The Trane Company will not assume responsibility for
3
equipment damage resulting from accumulation of
1
condensate on the unit electrical components.
FWD 14
2
3
1

Training

FWD 20
2
3
To assist you in obtaining the best use of it and
maintaining it in perfect operating condition over a long
period of time, the manufacturer has at your disposal
a refrigeration and air conditioning service school. The
principal aim of this is to give operators and technicians
a better knowledge of the equipment they are using,
or that is under their charge. Emphasis is particularly
given to the importance of periodic checks on the
unit operating parameters as well as on preventive
maintenance, which reduces the cost of owning the unit
by avoiding serious and costly breakdown.
RT-SVX060D-GB
UNT-PRC002-GB
Power level in dB(A), per Hz frequency band
125
250
500
55
50
42
57
54
47
58
57
50
57
51
45
58
54
48
60
58
50
57
51
45
58
54
48
60
58
50
56
62
50
61
66
55
63
69
58
57
63
51
61
66
55
63
69
58
Power level in dB(A), per Hz frequency band
125
250
500
56
55
55
63
62
60
66
65
63
62
58
55
66
63
60
70
67
63
62
58
55
66
63
60
70
67
63
66
65
65
73
72
69
78
76
73
68
72
64
76
76
68
78
79
71
General information
1000
2000
4000
37
37
31
40
30
38
42
32
40
42
34
33
45
38
39
48
40
42
42
34
33
45
38
39
48
40
42
48
39
38
53
47
46
56
50
50
49
40
39
53
47
46
56
50
50
1000
2000
4000
53
46
45
60
53
53
62
56
55
58
51
48
62
56
55
65
59
59
58
51
48
62
56
55
65
59
59
65
57
50
71
64
59
75
69
64
64
56
52
71
65
61
74
69
66
Overall power
8000
dB(A)
30
46
40
50
43
53
28
48
35
51
39
54
28
48
35
51
39
54
36
56
45
60
49
63
37
57
45
60
49
63
Overall power
8000
dB(A)
42
57
53
64
57
67
44
61
52
66
57
69
44
61
52
66
57
69
46
68
57
74
63
78
50
69
61
75
66
78
5 1 1